Pay in installments of $6.26 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Oct 7 - Oct 12
For Your Every Summer RSVP, with Code: SUMMER15
Description
LC1K0610R7Main Range TeSys Product or component type Contactor Product name TeSys K Device short name LC1K Device application Control Contactor application Motor control Complementary Utilisation category AC 3 AC 4 Poles description 3P Power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 690 V AC 50 60 Hz Signalling circuit: <= 690 V AC 50 60 Hz [Ie] rated operational current 6 A at <= 440 V AC AC 3 for power circuit Control circuit
Main
| Range | TeSys |
| Product or component type | Contactor |
| Product name | TeSys K |
| Device short name | LC1K |
| Device application | Control |
| Contactor application | Motor control |
Complementary
| Utilisation category | AC-3 AC-4 |
| Poles description | 3P |
| Power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 6 A at <= 440 V AC AC-3 for power circuit |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 440 V AC 50/60 Hz |
| Motor power kW | 1.5 kW at 220...230 V AC 50/60 Hz AC-3 2.2 kW at 380...415 V AC 50/60 Hz AC-3 3 kW at 440 V AC 50/60 Hz AC-3 3 kW at 480 V AC 50/60 Hz AC-3 3 kW at 500...600 V AC 50/60 Hz AC-3 3 kW at 660...690 V AC 50/60 Hz AC-3 1.5 kW at 400 V AC 50/60 Hz AC-4 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Auxiliary contacts type | Type instantaneous 1 NO |
| Signalling circuit frequency | <= 400 Hz |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Mounting support | Plate Rail |
| Tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm |
| Operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 6 A AC-3 at Ue <= 440 V |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net weight | 0.18 kg |
Environment
| Standards | BS 5424 IEC 60947 NF C 63-110 VDE 0660 |
| Product certifications | CSA UL |
| IP degree of protection | IP2x conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Ambient air temperature for storage | -50…80 °C |
| Operating altitude | 2000 m without |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant EU RoHS Declaration |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.1 ★★★★★
Based on 13 reviews
Sort
Product Reviews
★★★★★ 5
This tire sealant works very well
Size: 16 oz
So far so good.
Cheaper and easier that tubing a leaking tire
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 24, 2026
★★★★★ 3
Hard to install as instructed.
Size: 32 oz
Nearly impossible to get it in the tire through the valve. Yes I removed the valve core.
Broke the bead on the tire and dumped it in. That worked great! So far no leaks.
They should definitely redesign the installation method.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 28, 2026
★★★★★ 5
Been using it for 15 years! Not sure where the Neg reviews come from?
Size: 16 oz
I've been using Liquitube since around 2010. I use it religiously in my ATVs and lawn tractor tires. Since I've been using this stuff, I've never had a flat before. I've pulled out nails and slivers of steel out of my ATV tires but yet none of them lose air or go flat.
I think some of the negative reviews come from improper use of the product or not enough of the product is being used in the tires. I think this come from variance in formula charts that Liquitube has had in the past on their bottles and on their website. The chart on their website wouldn't match the formula that was provided on the bottle. So I think alot of people get mixed up and not knowing the correct amount to add to each tire. Now Liquitube just puts pictures on the side of the bottle with an ounce measurement below each picture to tell people how to use it. But even that can be confusing. For instance, take the picture of the ATV that they show. Below the ATV it says 32oz. Now some people probably think the 32oz is for the entire ATV. Well that isn't the case. They want you to use 32oz Per Tire! Years ago Liquitube even used to say on the bottle to use 32oz per tire on an ATV. Now they just show a picture with an amount below it.
Now you'll come to find out that the 32oz they recommend doesn't match up to the formula they tell you to use to calculate how much each tire is supposed to get. So if you use the formula provided, you come to find that it calculates out to use less product per tire than what the bottle tells you to use. So that's very confusing as well.
So if you use it long enough, you'll be able to know how much each tire will need from experience. Just make sure there's enough on the inside of the tire to coat the entire inside as well as leaving a bit left over to circulate in the tire so it can be ready for a large puncture if that ever happens.
All in all, it's a good product that does what it claims. It lasts for as long as the tire does and it doesn't freeze up in the cold either! 5 stars!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 13, 2026
★★★★★ 5
Worked on slow leak… one month already!!!
Style: 18oz
Edit: Still holding proper pressure at 2-months !!!
Had a slow leak where my tire went from 44psi to ~18psi over 2-3 days… Dashboard light would let me know every few days that I had a tire problem and I would inflate the tire back up to 44psi… Anyway, I used this product and filled air back to 44 psi and it’s held the pressure for a month already !!!! Be sure to deflate tire to ~15 PSI before adding the product… it only took about 30 seconds to empty the container into my tire with the tire pressure low. Very happy with this product !!!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 6, 2026
★★★★★ 5
Excellent stuff!
Style: 18oz
Used this on a Z-Trac with a flat and it fixed it and has held up for over 8 months.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 11, 2026
recommand products
ALLSTAR PERFORMANCE Bump Spring Cup 1/2in 1.200 Cup Step OD ALL64353
40.95
ALLSTAR PERFORMANCE 5/8 Steel Tube 9in 7/8in OD ALL57162
40.95
FK ROD ENDS 7/8-3/4 Hi-Misalignment Bushing 14-12HB
40.95
ALLSTAR PERFORMANCE Adapter Fittings 10mm-1.5 to 1/8 NPT 2pk ALL50040
40.95
REDHORSE PERFORMANCE 8AN Swivel Hose Ends Black 150 -273717
40.95