Pay in installments of $28.12 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 22 - Jul 27
For Your Every Summer RSVP, with Code: SUMMER15
Description
UA-Glo® Firefly/Nano Dual Luciferase Assay SystemProduct Specification Synonyms Firefly Nano Stability & Storage Store at 20C within three months, and at 80C beyond three months. Valid for 12 months. Background The dual luciferase reporter gene system is widely used in mammalian cell function research, including cell metabolism, signaling pathways, transcription factors, gene function, and drug screening. In the dual luciferase reporter system, one luciferase serves as the experimental reporter gene
Product Specification
| Synonyms | Firefly/Nano双荧光素酶检测试剂盒 |
| Stability & Storage | Store at -20°C within three months, and at -80°C beyond three months. Valid for 12 months. |
Background
The dual-luciferase reporter gene system is widely used in mammalian cell function research, including cell metabolism, signaling pathways, transcription factors, gene function, and drug screening. In the dual-luciferase reporter system, one luciferase serves as the experimental reporter gene to indicate the activity of the target under study, while the other luciferase acts as the control reporter gene to normalize the activity of the experimental reporter gene. This minimizes experimental errors caused by factors such as transfection efficiency, cell count, cell lysis effects, and sample volume.
The UA-Glo® Firefly/Nano Dual-Luciferase Assay Kit enables the detection of Firefly luciferase and Nano-Luc (Nano-Luciferase) expression in the same sample, offering advantages such as high sensitivity, excellent stability, reproducibility, and ease of use. Compared to traditional Firefly/Renilla luciferase dual-luciferase detection systems, the UA-Glo® Firefly/Nano Dual-Luciferase Assay Kit provides higher signal values, greater sensitivity, and improved tolerance to compound effects on luciferase, significantly reducing false-positive results in high-throughput screening due to compound interference with luciferase activity.
Components
The Firefly/Nano Dual Luciferase Assay Kit consists of R1 reagent, R2 buffer, and R2 substrate. The R1 reagent is filled in brown bottles, the R2 buffer is filled in white bottles, and the R2 substrate is aliquoted in microtubes. The specifications are as follows:
Specification |
R1 Reagent |
R2 Buffer |
R2 Substrate |
Detectable 96-well Plate Wells |
Detectable 384-well Plate Wells |
10 ml |
10 ml |
10 ml |
100μl |
200 |
1,000 |
100 ml |
100 ml |
100 ml |
1ml |
2,000 |
10,000 |
10x100 ml |
10x100 ml |
10x100 ml |
10x1ml |
2,000 |
100,000 |
Protocol
1.Seed cells at an appropriate density in 96-well or 384-well white cell culture plates. Transfect the cells with vectors expressing firefly luciferase and Nano-Luc luciferase as required by the experiment, or directly use stable cell lines expressing these dual luciferases.
2.Treat the cells according to experimental requirements and culture for an appropriate duration.
3.Remove the cell culture plate and equilibrate it to room temperature (22-25°C) [Note 1].
4.Remove the detection reagents and equilibrate them to room temperature. R1 reagent can be used directly. R2 substrate is a 100x concentrated solution and should be diluted with R2 buffer to prepare a 1x R2 working solution before use [Note 2].
5.Add an equal volume of R1 reagent to the cell culture plate as the cell culture medium. For example, add 50µl of R1 to a 96-well plate containing 50µl of cell culture medium [Note 3].
6.Shake the plate for 3 minutes, then place it in the dark for an additional 5 minutes to allow lysis.
7.Measure the luminescence signal using a fluorescence plate reader. This reading represents firefly luciferase activity [Note 4].
8.Add an equal volume of R2 working solution to each well of the cell culture plate.
9.Shake the plate for 3 minutes to ensure thorough mixing, then place it in the dark for an additional 10 minutes to allow lysis.
10.Measure the luminescence signal using a luminescence plate reader. This reading represents Nano-Luc luciferase activity.
11.Perform data processing as required by the experiment [Note 5].
Guidelines
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy