UniOne® TR-FRET Human cAMP Hirange Detection KitProduct Specification Host Human Stability & Storage 80 Background The kit employs homogeneous time resolved fluorescence (TR FRET) technology, enabling precise measurement of cellular cAMP production. This method allows rapid detection of cAMP accumulation changes during the inhibition or activation of Gs or Gi signaling pathways. As shown in the figure, the Eu labeled anti cAMP antibody (TR FRET donor) and the Ac labeled cAMP (TR FRET acceptor) bind

Product Specification


Host Human
Stability & Storage

-80℃

Background

The kit employs homogeneous time-resolved fluorescence (TR-FRET) technology, enabling precise measurement of cellular cAMP production. This method allows rapid detection of cAMP accumulation changes during the inhibition or activation of Gs or Gi signaling pathways.

As shown in the figure, the Eu-labeled anti-cAMP antibody (TR-FRET donor) and the Ac-labeled cAMP (TR-FRET acceptor) bind directly. When the donor antibody and acceptor antibody are in proximity, excitation of the donor antibody triggers fluorescence resonance energy transfer (FRET) to the acceptor antibody, resulting in a specific 665 nm emission signal. When cAMP from cell samples or standard curves is present, it competes with the Ac-labeled cAMP for binding to the Eu-labeled anti-cAMP antibody, thereby reducing the FRET signal. This specific signal is inversely proportional to the extent of interaction between the Eu-labeled anti-cAMP antibody and the Ac-labeled cAMP. The homogeneous assay is simple to perform and requires no washing steps.

Components

Component

Concentration

100T

500T

2500T

10000T

Storage Temperature

cAMP calibrator

4mM

5μL

5μL

25μL

100μL

-80℃

Anti-cAMP Eu antibody

100×

5μL

25μL

125μL

500μL

-80℃

cAMP-Ac

100×

5μL

25μL

125μL

500μL

-80℃

Lysis & Detect Buffer

1×

2mL

10mL

50mL

200mL

-80℃

Stimulation Buffer (without IBMX)

1×

2mL

10mL

50mL

200mL

-80℃


Note: Aliquot immediately upon first thawing and store at the recommended temperature. Avoid storage after dilution and repeated freeze-thaw cycles.

Protocol

Here is the translated content in English, maintaining the original formatting:```html

1. Reagent Preparation

1.1 Thaw all reagents to room temperature before use. The reaction system for the 384-well plate is 20μL (reagent volumes are shown in the table below). Calculate the required volume before preparation. The following preparation is for reference only, using 500 reactions as an example.

Table 1. Reagent Preparation and Volumes

Reagent Name

Preparation

Volume per Well (μL)

Anti-cAMP Eu antibody

Take 25μL of Anti-cAMP Eu antibody stock, dilute to 2.5mL with Lysis & Detect Buffer, mix well for use.

5μL

cAMP-Ac

Take 25μL of cAMP-Ac stock, dilute to 2.5mL with Lysis & Detect Buffer, mix well for use;

5μL


1.2 Gradient Dilution of Test Samples

Prepare according to experimental conditions. The following is for reference only.

Using cAMP calibrator as an example, the diluent is Stimulation Buffer. Adjust sample concentrations as needed.

Table 2. cAMP Calibrator Preparation Table

Preparation Concentration (nM)

Final Concentration (nM)

Preparation Method

1

40,000.000

10,000.000

1μL of 4mM stock + 99μL Stimulation Buffer

2

13,333.333

3,333.333

20μL of ① + 40μL Stimulation Buffer

3

4,444.444极left;">

1,111.111

20μL of ② + 40μL Stimulation Buffer

4

1,481.481

370.370

20μL of ③ + 40μL Stimulation Buffer

5

493.827

123.457

20μL of ④ + 40μL Stimulation Buffer

6

164.609

41.152

20μL of ⑤ + 40μL Stimulation Buffer

7

54.870

13.717

20μL of ⑥ + 40μL Stimulation Buffer

8

18.290

4.572

20μL of ⑦ + 40μL Stimulation Buffer

9

6.097

1.524

20μL of ⑧ + 40μL Stimulation Buffer

10

2.032

0.508

20μL of ⑨ + 40μL Stimulation Buffer

11

0.677

0.169

20μL of ⑩ + 40μL Stimulation Buffer

⑫

0.226

0.056

20μL of ⑪ + 40μL Stimulation Buffer

Blank

0

0

40μL of 1× Stimulation Buffer


1.3 Pre-Treatment for Cell-Based Experiments

①Stimulation Buffer is used for diluting cells and stimulating drugs. The Stimulation Buffer provided in the kit does not contain IBMX. Add an appropriate concentration of IBMX to prevent cAMP degradation, depending on experimental objectives.

②Before formal experiments, optimize the number of cells per well and the incubation time with drugs based on cell and drug characteristics to ensure cAMP levels fall within the linear range of the calibration curve.

2. Sample Loading and Controls

2.1 cAMP Standard Curve: 5μL of gradient-diluted cAMP reference, 5μL Stimulation Buffer, 5μL Anti-cAMP Eu antibody working solution. Incubate for 10min, then add 5μL cAMP-Ac.

2.2 Test Samples: 5μL of gradient-diluted sample, 5μL Stimulation Buffer, 5μL Anti-cAMP Eu antibody working solution. Incubate for 10min, then add 5μL cAMP-Ac.

2.3 Cell-Based Experiments: Based on pre-experiment results, add 5μL cells and 5μL gradient-diluted drug per well. After incubation (optimized time), add 5μL Anti-cAMP Eu antibody working solution, incubate at room temperature for 10min, then add 5μL cAMP-Ac.

2.4 Negative Control (NC): 5μL Stimulation Buffer instead of sample or 5μL untreated cells.

cAMP Standard Curve

Test Samples

Cell Experiments

Negative Control (NC)

Step 1

5μL cAMP calibrator

5μL test sample

5μL cells

5μL Stimulation Buffer or 5μL cells

5μL Stimulation Buffer

5μL Stimulation Buffer极left;">

5μL drug※

5μL Stimulation Buffer

5μL Anti-cAMP Eu antibody working solution

Incubate at room temperature for 10min

Step 2

5μL cAMP-Ac

Seal plate, centrifuge at 1000rpm for 1min to mix,

incubate at room temperature for 120min, then read plate.


•Optimize incubation time for cells and drugs experimentally. Add subsequent reagents after drug stimulation.

3.Detection

Measure using a TR-FRET-compatible microplate reader. Excitation at 320/340nm, emission at 620nm and 665nm.

【Data Analysis】

1) Calculate signal ratio (Ratio): (665nm signal / 620nm signal) × 10000.

Ratio = (665/620) × 10000

2) Calculate CV (%):

CV (%) = (Standard Deviation / Mean Ratio) × 100%

【Example Data】

The following data is for illustration only and may vary depending on the reader.

Note: *Example data only. Recommended plate: 384-well, white, shallow-well.

```
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 87259346728

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.3 ★★★★★
Based on 28 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
C
Verified Purchase
Cali Mom
Phoenix, US
★★★★★ 5
Perfect size, high quality
Size: 7.7" x 7.7" x 1.7", Color: Black (Metal Silvered)
I had a previous catch all tray that I bought on amazon, it used buttons on the 4 corners to turn a flat cardboard into a tray. Over time, the catch all tray got filled up, not just with a wallet, keys and eyeglasses but eventually business cards and other knick knacks. With all the items inside the tray, sometimes the buttons would start to pop out. It wasn't awful, more of an annoyance. But it was time for me to find a more durable tray. I looked on amazon and added 6 different trays that had "potential" into my shopping cart. Then I carefully evaluated each one and deleted them out of my cart until there was only one left. Some had multiple compartments. Some were larger than this one. I felt the ones with compartments would limit my ability to put the things I want in there. Also, I didn't want it so big that it took up too much desk space. Ultimately, I felt this was the perfect size. I'm extremely happy with it, the quality is really nice and it looks and feels durable. No more loose buttons and spilled knick knacks.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 14, 2024
D
Verified Purchase
Denise
Massapequa, US
★★★★★ 5
Keeps clutter away
Size: 7.7" x 7.7" x 1.7", Color: Black (Metal Silvered)
This works great to corral all my notes I write on post its or small notes. Keeping them hidden from the desk top b/c or the depth but still visible to me. Much better than keeping on the plotter. Looks great in quality .
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 25, 2025
M
Verified Purchase
MovieGuy
Pawtucket, US
★★★★★ 5
Attractive, Simple, And Well-Made
Size: 7.7" x 7.7" x 1.7", Color: Orange (Metal Glided)
I use this as a "catchall". A place to stash things like my wallet and keys when I enter the door, so that I don't use them (I had been prone to that!). It serves it's purpose well. It's both sturdy and attractive, and a good size for a "catchall". Recommended for those like me who need such things.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 8, 2024
K
Verified Purchase
Kirstin Gramith
Battle Creek, US
★★★★★ 4
Good quality, orange color
Size: 7.7" x 7.7" x 1.7", Color: Orange (Metal Glided), Size: 7.7" x 7.7" x 1.7", Color: Orange (Metal Glided)
The quality is surprisingly good but the color is much more orange toned in person.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 17, 2024
K
Verified Purchase
kenneth
New York, US
★★★★★ 5
Holder
Size: 7.7" x 7.7" x 1.7", Color: Black (Metal Silvered)
It’s great for my keys and wallet and other stuff I use it every day
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 30, 2025

recommand products