Pay in installments of $46.03 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Sep 8 - Sep 13
For Your Every Summer RSVP, with Code: SUMMER15
Description
Rat Na-K-ATPase ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20
Product Specification
| Usage |
Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37℃ constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing. 2. Plasma: Collect specimens using EDTA or heparin as an anticoagulant and centrifuge at 1000×g for 15 minutes at 2-8°C within 30 minutes of collection. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing. 3. Cell culture supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing. Pre-Test Preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare a gradient standard working solution: Add 1 mL of universal diluent to the lyophilized standard. Let stand for 15 minutes to completely dissolve, then gently mix (concentration 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 10 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Na-K-ATPase (Na-K-ATPase) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by HRP peroxidase and to yellow by acid. The intensity of the color is positively correlated with the amount of Na-K-ATPase (Na-K-ATPase) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Rat | |||||||||||||||||||||||||||||||||
| Synonym | Rat Na-K-ATPase ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Na-K-ATPase (Na-K-ATPase) is an enzyme present in the cell membranes of all animal cells (an electrically charged transmembrane ATPase). It plays several roles in cellular physiology. The Na⁺/K⁺-ATPase enzyme is active (i.e., it uses energy from ATP). For every ATP molecule used by the pump, three sodium ions are exported and two potassium ions are imported, resulting in a net output of positive charge per pump cycle. This enzyme belongs to the P-type ATPase family. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.156-10 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Serum, plasma, cell culture supernatant |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.3 ★★★★★
Based on 28 reviews
Sort
Product Reviews
★★★★★ 5
My Go-To Sublimation Paper — Flawless Results Every Time
Size: 8.5"x11", Size: 8.5"x11"
This is hands down the best sublimation paper I’ve used and the only one I continue to buy. I get a perfect transfer every single time—no fracturing, no fading, and no uneven results. The paper dries fast, which makes my workflow so much smoother, especially when I’m producing items in batches.
I use this regularly to make air fresheners and tote bags for my small business, and the color payoff is always vibrant and crisp. The transfer rate is excellent, and it works beautifully on light-colored, high-quality polyester and other sublimation-ready surfaces.
If you’re a small business owner or crafter who values consistency, quality, and ease of use, this paper is absolutely worth it. I highly recommend it and will continue to repurchase.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 24, 2026
★★★★★ 5
Best Sublimation Paper
Size: 8.5"x11"
I’ve been using A-Sub paper for my sublimation projects, and it is easily one of the best. The ink dries almost instantly once printed, so I don’t have to worry about smudging the design or getting those annoying "pizza wheel" marks from the printer rollers. The paper itself feels substantial and doesn't tear or curl easily. One of the biggest wins for me is that it never jams; it feeds through perfectly every time, saving me the frustration of wasting expensive ink and paper.
When I go to press my designs, the ink releases almost completely, leaving very little behind on the paper and putting all that color onto the project. The final results look super professional, with colors that are vibrant and sharp rather than looking faded or dull. It has worked perfectly for everything I’ve tried so far, and if you want a reliable paper that gives you consistent, high-quality results, this is definitely the one to get.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 25, 2026
★★★★★ 5
Ideal for sublimation beginners.
Size: 8.5"x11"
Asub sublimation paper has been excellent for my projects. The ink transfer is very good, the colors are vibrant and defined, and it dries quickly. It has helped me achieve clean and professional results, even as a beginner. Without a doubt, it's a reliable, high-quality paper for sublimation.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 15, 2026
★★★★★ 5
Excellent works great and I’m bang for your buck
Size: 8.5"x14"
I love this paper. It prints, nice and clear I will be buying more.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 30, 2026
★★★★★ 5
Very good for sublimation
Size: 8.5"x11"
Intact and very good for my sublimation
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 25, 2026
recommand products
Rook SmartTouch Prep Faucet with Pulldown Spray - Brilliance Luxe Gold 64974LF-GL Brizo
801.38
Air Gap for Kitchen - Polished Gold 69060-PG Brizo
69.86
Rook TempAssure Thermostatic Valve with 3-Function Diverter Trim - Venetian Bronze T75561-RB Brizo
555.75
Levoir Handle Kit For Pressure Balance Valve Trim - Brilliance Black Onyx HL60P98-BNX Brizo
151.50
Invari Pressure Balance Valve Trim Only (Less Handles) - Chrome T60P076-PCLHP Brizo
105.00