Description

LC1DT40BDMain Range TeSys Product name TeSys D Product or component type Contactor Device short name LC1D Contactor application Resistive load Utilisation category AC 1 Poles description 4P Power pole contact composition 4 NO [Ue] rated operational voltage Power circuit: <= 690 V AC 25 400 Hz Power circuit: <= 300 V DC [Ie] rated operational current 40 A (at <60 C) at <= 440 V AC AC 1 for power circuit Control circuit type DC standard [Uc] control circuit

Main
Range TeSys
Product name TeSys D
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
Poles description 4P
Power pole contact composition 4 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Control circuit type DC standard
[Uc] control circuit voltage 24 V DC
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 50 A 40 °C - 10 min for power circuit
120 A 40 °C - 1 min for power circuit
240 A 40 °C - 10 s for power circuit
380 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Electrical durability 1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Power dissipation per pole 3.2 W AC-1
Safety cover With
Mounting support Plate
Rail
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certifications CSA
UL
RINA
GOST
LROS (Lloyds register of shipping)
BV
GL
DNV
CCC
Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: connector 1 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: connector 2 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: connector 1 cable(s) 2.5…10 mm²flexible with cable end
Power circuit: connector 2 cable(s) 2.5…10 mm²flexible with cable end
Power circuit: connector 1 cable(s) 2.5…16 mm²solid without cable end
Power circuit: connector 2 cable(s) 2.5…16 mm²solid without cable end
Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat √ò 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 1.7 N.m - on connector - with screwdriver flat √ò 6 mm
Power circuit: 1.7 N.m - on connector - with screwdriver Philips No 2
Operating time 16...24 ms opening
53.55...72.45 ms closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 30 Mcycles
Maximum operating rate 3600 cyc/h 60 °C
Complementary
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits Drop-out: 0.1...0.25 Uc DC (at 60 °C)
Operational: 0.7...1.25 Uc DC (at 60 °C)
Time constant 28 ms
Inrush power in W 5.4 W (at 20 °C)
Hold-in power consumption in W 5.4 W at 20 °C
Auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit
Environment
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -5…60 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…70 °C at Uc
Operating altitude 3000 m without
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open: 8 Gn for 11 ms
Height 91 mm
Width 45 mm
Depth 107 mm
Net weight 0.425 kg
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive Compliant
EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 35184504969

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.6 ★★★★★
Based on 14 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
N
Verified Purchase
Nobody
Boise, US
★★★★★ 5
GREAT PROPDUCT
Size: 2 fl oz
EXCELLENT
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 27, 2026
A
Verified Purchase
Amazon Customer
West Palm Beach, US
★★★★★ 4
Cleans Out Working Carburetors
Size: 2 fl oz
I recommend this product for engines that will in fact start but not run well. I highly recommend it for that specific purpose, which it is designed for. It cleans the inner workings of the carburetor. Of course, you will have a cleaner carburetor if you take it apart and clean it with proper tools and a proper carburetor cleaner. You spray it in the gas tank, start the engine, and let it run a bit. It will not start an engine with a totally plugged up carburetor. Nothing is going to do that. Nor is it a fuel stabilizer, as one previous reviewer seemed to think. Nor is it a product to be used to bring life back to stale gasoline, as another reviewer seemed to think. The only thing to do with stale gasoline is drain it out and pitch it. Nor is it a product to be used for cleaning a carburetor you have taken apart to clean. You should use a proper carburetor cleaner for that purpose. I've given it four stars because it cleans out mildly plugged up carbs. It is not a miracle solution for really neglected carbs as the name suggests.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 12, 2020
R
Verified Purchase
Ray
Lake Worth, US
★★★★★ 5
Helps fixing small engines
Size: 2 fl oz
⭐⭐⭐⭐⭐⭐⭐
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 16, 2026
J
Verified Purchase
JustAGeek
Chelsea, US
★★★★★ 5
It works like magic, saved me $150.
Size: 2 fl oz
I filled 1/4 tank of gas into my snowblower which I could not started, sprayed about 15 seconds of Start Your Engines, rock snowblower to mix well, let it sat for an hour. I pulled string and yet couldn't start engine. Unscrewed spark plug and spray some into cylinder, put the spark plug back and pull the string. ENGINE STARTED!!! SAVED ME AT THE LEAST $150.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 1, 2026
B
Verified Purchase
Bear
Cuba, US
★★★★★ 5
Great
Size: 2 fl oz
Great
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 22, 2026

recommand products