SKU: 94477862801

Mouse IL-12 p35 ELISA Kit

Sale price$171.42 Regular price$190.47
Save 10%

Pay in installments of $47.62 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 20 - Aug 25

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Mouse IL-12 p35 ELISA KitProduct Specification Usage Sample Processing and Requirements 1. Serum: Place the whole blood specimen collected in a serum separator tube at room temperature for 2 hours or at 4C overnight, then centrifuge at 1000g for 20 minutes. Remove the supernatant and store it at 20C or 80C. However, repeated freezing and thawing should be avoided. 2. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Within 30 minutes of collection,

Product Specification

Usage

Sample Processing and Requirements


1.
Serum: Place the whole blood specimen collected in a serum separator tube at room temperature for 2 hours or at 4°C overnight, then centrifuge at 1000×g for 20 minutes. Remove the supernatant and store it at -20°C or -80°C. However, repeated freezing and thawing should be avoided.


2.
Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Within 30 minutes of collection, centrifuge at 1000×g for 15 minutes at 2-8°C. Remove the supernatant and test it. Alternatively, store it at -20°C or -80°C. However, repeated freezing and thawing should be avoided.


3. Tissue Homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove any residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly freeze-thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes. Remove the supernatant for analysis.


4. Cell culture supernatant or other biological specimens: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.


Note: Hemolysis of the specimen will affect the final test results, so hemolyzed specimens should not be used for this test.


Reagent Preparation After removing the kit from the refrigerator, allow it to equilibrate to room temperature before use.


Dilution of 20× Wash Buffer: Dilute 1:20 with distilled water, i.e., add 1 part 20× Wash Buffer to 19 parts distilled water.


Procedure


1. After equilibration at room temperature for 20 minutes, remove the desired strips from the aluminum foil bag. Seal the remaining strips in a ziplock bag and return them to 4°C.


2. Set up standard wells and sample wells. Add 50 μL of standard solution of varying concentrations to each standard well.


3. Add 50 μL of the sample to be tested to the sample wells; leave blank wells untouched.


4. Add 100 μL of horseradish peroxidase (HRP)-labeled detection antibody to each standard and sample well, except for the blank well. Seal the wells with sealing film and incubate at 37°C in a waterbath or incubator for 60 minutes.


5. Discard the liquid, pat dry on absorbent paper, and fill each well with wash buffer (350 μL). Let stand for 1 minute, then discard the wash buffer and pat dry on absorbent paper. Repeat this process five times (a plate washer can also be used).


6. Add 50 μL each of substrates A and B to each well and incubate at 37°C in the dark for 15 minutes.


7. Add 50 μL of stop solution to each well. Within 15 minutes, measure the OD value of each well at a wavelength of 450 nm.


Calculation of Experimental Results: Using the OD value of the measured standard as the horizontal axis and the concentration of the standard as the vertical axis, draw a standard curve on graph paper or using relevant software. Obtain a linear regression equation. Substitute the OD value of the sample into the equation to calculate the sample concentration.



Standard Curve

Sensitivity The minimum detectable concentration was less than 1.0 pg/mL.
Species Reactivity Mouse
Theory The kit utilizes a double-antibody, one-step sandwich enzyme-linked immunosorbent assay (ELISA). Samples, standards, and HRP-labeled detection antibodies are sequentially added to microwells pre-coated with mouse interleukin-12 (IL-12; p35) capture antibodies. The assay is incubated and thoroughly washed. The color is developed using the substrate TMB, which converts to blue under peroxidase catalysis and to yellow under acid. The intensity of the color is positively correlated with the amount of mouse interleukin-12 (IL-12; p35) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Detection Type Used for in vitro quantitative detection of the content of mouse interleukin 12 (IL-12; p35) in serum, plasma, tissue homogenate and related liquid samples.
Composition

Name

96 T

Remarks

Microwell enzyme plate

12 wells×8 strips

None

Standard product

0.3mL*6 tubes

None

Sample diluent

6mL

None

Detection antibody-HRP

10mL

None

20× wash buffer

25mL

Dilution according to the instructions

Substrate A

6mL

None

Substrate B

6mL

None

Stop solution

6mL

None

Seal film

2 sheets

None

Remarks:

1. The concentrations of the standard solutions are: 200, 100, 50, 25, 12.5, and 6.25 pg/mL.

2. After testing a large number of normal specimens, the normal concentrations of the specimens are all within the detection range provided by the kit. During the experiment, 50 μL of sample can be directly loaded. If some sample values exceed the maximum standard concentration, the sample can be appropriately diluted with sample diluent before the experiment.

General Notes

1. Strictly follow the specified incubation time and temperature to ensure accurate results. All reagents must reach room temperature (20-25°C) before use. Refrigerate reagents immediately after use.

2. Improper plate washing can lead to inaccurate results. Ensure that the liquid in the wells is as dry as possible before adding substrate. Do not allow the microwells to dry out during incubation.

3. Remove any residual liquid and fingerprints from the bottom of the plate, otherwise it will affect the OD value.

4. The substrate developer solution should be colorless or very light in color. Substrate solution that has turned blue should not be used.

5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.

6. Avoid direct exposure to strong light during storage and incubation.

7. Allow the sealed bag to equilibrate to room temperature before opening to prevent water droplets from condensing on the cold plate strips.

8. No reaction reagents should come into contact with bleaching solvents or the strong fumes emitted by bleaching solvents.

Any bleaching component will destroy the biological activity of the reagents in the kit.

9. Do not use expired products.

10. If there is a possibility of disease transmission, all samples should be managed properly and the samples and detection devices should be handled according to the prescribed procedures.

Storage Temp. Unopened test kit, stored at 2-8°C, has a shelf life of 6 months.
Test Range 6.25 pg/mL – 200 pg/mL.
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 94477862801

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.5 ★★★★★
Based on 15 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
S
Verified Purchase
Sarah A
Bozeman, US
★★★★★ 5
oh wow
Format: Kindle
I just knew there was something about Cooper! I’m wondering if he’s about to be included but damn I’m glad he’s at least not a rapist and creepy guy, he just got called on assignment and had to go! This should be interesting! She’s gonna run and then what’s his face is gonna grab her. I’m worried! Wow that was a great book and cliffhanger! Loving this!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 27, 2025
A
Verified Purchase
Ashley Morgan
Boise, US
★★★★★ 5
ABSOLUTELY A MUST for Omegaverse Girls!!!
I ABSOLUTELY LOVE Jillian West and her books!!! I’m so happy I already bought book two and now I have to buy the others for the Assurance Security series!! Not gonna lie Val kind of annoyed me at the beginning but she grew on me!! Her men are chef’s kisses!!! Holt annoys me some but I can let it slide. I already bought part two so I’m going to be reading that in between work phone calls!!!! DON’T TELL MY BOSS 😂😂😂😂
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 30, 2025
C
Verified Purchase
Carmen Alicea
Natrona Heights, US
★★★★★ 4
Baby bumps and bodyguards
Format: Kindle
Dark, emotional, and unexpectedly tender, Not Ready is an omegaverse romance that delivers found family feels, fierce protectiveness, and a very pregnant heroine who refuses to break. Vale’s on the run from a stalker, but lands in the arms of three private security alphas, cue the swoony tension, fake marriage twist, and slow-burn heat. It’s a little gritty, a little soft, and a whole lot addictive. If you love protective alphas, high stakes, and heroines with quiet strength, this one’s a must-read.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 18, 2025
S
Verified Purchase
Shianne Whipple
New York, US
★★★★★ 5
Strong Omegaverse Comfort and a Attention Grabbing Plot
Format: Kindle
Jillian West never misses when it comes to Omegaverse, and Not Ready is no exception. This story was the perfect blend of cozy comfort and emotional depth while still delivering a strong plot. Vale is such a powerful heroine, she is strong, capable, and determined but I love that she still allows her pack to love and take care of her. It’s that balance of independence and vulnerability that makes her so relatable. The relationship dynamics were amazing: Bishop is steadfast and completely head over heels, Mercy is skeptical but protective in his own way, and Holt is the hesitant one whose slow fall is so satisfying to watch unfold. The romance hits that sweet spot between insta-love and cautious build, keeping me hooked the entire way through. And that ending. Oh my god, the cliffhanger! I need the next book in this duet immediately.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 28, 2025
N
Verified Purchase
NLB
Fort Morgan, US
★★★★★ 5
Interesting
Format: Kindle
So I will say I enjoyed the story, for sure had its moments where it dragged but it was a great story. I really liked that omegas picked their alphas/make the pack. Normally the Alphas make it and the omega fits in with them which is great but I enjoyed this new version where all the power basically went to the omega. It was a nice change of pace. I can admit some of the weird bedroom stuff with her being pregnant was odd, it’s really not hard to do stuff when pregnant (I know I’ve had two and it’s normal and even encouraged at the end especially if you want the baby out). But I like the story as a whole and will read the second, I do hope the next one isn’t dragged bc it stopped being action or tense after she met her alphas and I don’t think it was brought up or properly done when they tried to do it. More sweet after she left.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 11, 2024

recommand products